diff --git a/src/main/resources/scripts/Plugins/NoiSee/NoiSee_Bead_Analysis.ijm b/src/main/resources/scripts/Plugins/NoiSee/NoiSee_Bead_Analysis.ijm index 02a927a4786972a16d0edfae90c0973cfe2bc965..a96aaac7107575b7566c442461402602aed2309e 100644 --- a/src/main/resources/scripts/Plugins/NoiSee/NoiSee_Bead_Analysis.ijm +++ b/src/main/resources/scripts/Plugins/NoiSee/NoiSee_Bead_Analysis.ijm @@ -1,5 +1,5 @@ //////////// NoiSee Beads Analysis /////////////////////////////////////////////////////// -// Signal-to-Noise-Ratio evaluation macro +// Signal-to-Noise-Ratio evaluation suite // written by Kai Schleicher, Niko Ehrenfeuchter, IMCF Basel // licence: GPLv3 @@ -16,7 +16,7 @@ //////// Script Parameters, see https://imagej.net/Script_Parameters for details -#@ String (visibility=MESSAGE, label="NoiSee -", value="Beads SNR analysis", persist=false) msg_title +#@ String(visibility=MESSAGE, label="NoiSee -",value="Beads SNR analysis",persist=false) msg_title #@ File(label="Beads time-series image",description="2D time-lapse acquisition of fluorescent beads") beadsimage #@ Integer(label="Beads diameter (in pixels)",description="approximate bead diameter (in pixels)",value=15) beads_diameter #@ Integer(label="Find Maxima noise tolerance",description="typical values: [PMT=50] [HyD (photon counting)=10] [Camera=500]",value=50) beads_noisetolerance @@ -24,7 +24,7 @@ #@ Boolean(label="Save additional measurements",description="store 'StdDev', 'SNR', 'Mean' and 'bleaching' measurements",value="false") save_measurements #@ Boolean(label="Save results as PDF",description="generate a PDF with images and plots",value="true") save_pdf #@ Boolean(label="Keep ROI images open",description="if disabled ROI visualizations will only be added to PDF",value="false") keep_roiimages -#@ String (visibility=MESSAGE, label="Note:", value="all currently open images will be closed", persist=false) msg_note_close +#@ String(visibility=MESSAGE,label="Note:",value="all currently open images will be closed",persist=false) msg_note_close // valid log levels: 0 (quiet), 1 (info messages), 2 (debug messages) diff --git a/src/main/resources/scripts/Plugins/NoiSee/NoiSee_Fluorescein_Analysis.ijm b/src/main/resources/scripts/Plugins/NoiSee/NoiSee_Fluorescein_Analysis.ijm index b83502635eb0546d81ce933604bef962d72094d5..7ac98722ec69290267a2912379df2a74b943e277 100644 --- a/src/main/resources/scripts/Plugins/NoiSee/NoiSee_Fluorescein_Analysis.ijm +++ b/src/main/resources/scripts/Plugins/NoiSee/NoiSee_Fluorescein_Analysis.ijm @@ -1,5 +1,5 @@ //////////// NoiSee Fluorescein Analysis /////////////////////////////////////////////////////// -// Signal-to-Noise-Ratio evaluation macro +// Signal-to-Noise-Ratio evaluation suite // written by Kai Schleicher, Niko Ehrenfeuchter, IMCF Basel // licence: GPLv3